Bienvenue à visiter Élément Technology Co., Ltd.!

+86 15361839241 +86 0755-23603516
Photos Le fabricant# Stocks Prix Quantité Tableau Packaging Series ProductStatus CableType NumberofConductors WireGauge ConductorStrand ConductorMaterial Jacket(Insulation)Material Jacket(Insulation)Diameter ShieldType Length JacketColor Ratings Features Voltage OperatingTemperature Usage
E2204S.30.86

E2204S.30.86

CABLE 4COND 18AWG NAT SHLD 500'

Prysmian Group

2945 0.00
- +

Ajouter au panier

Demander

E2204S.30.86

Datenblatt

Bulk - Discontinued at Mosen Multi-Conductor 4 18 AWG 7/26 Copper, Bare Poly-Vinyl Chloride (PVC), Plenum 0.185 (4.70mm) Foil 500.0' (152.4m) Natural - Drain Wire 300 V 0°C ~ 75°C Alarm, Security, Sound
E2036S.30.10

E2036S.30.10

CABLE 6COND 18AWG GRY SHLD 100'

Prysmian Group

2744 0.00
- +

Ajouter au panier

Demander

E2036S.30.10

Datenblatt

Bulk - Discontinued at Mosen Multi-Conductor 6 18 AWG 7/26 Copper, Bare Poly-Vinyl Chloride (PVC) 0.221 (5.61mm) Foil 100.0' (30.5m) Gray - Drain Wire, Rip Cord 300 V -20°C ~ 75°C Alarm, Security, Sound
E2102S.30.86

E2102S.30.86

CABLE 2COND 22AWG NAT SHLD 100'

Prysmian Group

2883 0.00
- +

Ajouter au panier

Demander

E2102S.30.86

Datenblatt

Bulk - Discontinued at Mosen Multi-Conductor 2 22 AWG 7/30 Copper, Bare Poly-Vinyl Chloride (PVC), Plenum 0.128 (3.25mm) Foil 100.0' (30.5m) Natural - Drain Wire 300 V 0°C ~ 75°C Alarm, Security, Sound
E2104S.30.86

E2104S.30.86

CABLE 4COND 22AWG NAT SHLD 100'

Prysmian Group

2184 0.00
- +

Ajouter au panier

Demander

E2104S.30.86

Datenblatt

Bulk - Discontinued at Mosen Multi-Conductor 4 22 AWG 7/30 Copper, Bare Poly-Vinyl Chloride (PVC), Plenum 0.147 (3.73mm) Foil 100.0' (30.5m) Natural - Drain Wire 300 V 0°C ~ 75°C Alarm, Security, Sound
E2106S.30.86

E2106S.30.86

CABLE 6COND 22AWG NAT SHLD 100'

Prysmian Group

2271 0.00
- +

Ajouter au panier

Demander

E2106S.30.86

Datenblatt

Bulk - Discontinued at Mosen Multi-Conductor 6 22 AWG 7/30 Copper, Bare Poly-Vinyl Chloride (PVC), Plenum 0.176 (4.47mm) Foil 100.0' (30.5m) Natural - Drain Wire 300 V 0°C ~ 75°C Alarm, Security, Sound
E2203S.30.86

E2203S.30.86

CABLE 3COND 18AWG NAT SHLD 100'

Prysmian Group

2805 0.00
- +

Ajouter au panier

Demander

E2203S.30.86

Datenblatt

Bulk - Discontinued at Mosen Multi-Conductor 3 18 AWG 7/26 Copper, Bare Poly-Vinyl Chloride (PVC), Plenum 0.169 (4.29mm) Foil 100.0' (30.5m) Natural - Drain Wire 300 V 0°C ~ 75°C Alarm, Security, Sound
E2204S.30.86

E2204S.30.86

CABLE 4COND 18AWG NAT SHLD 100'

Prysmian Group

3210 0.00
- +

Ajouter au panier

Demander

E2204S.30.86

Datenblatt

Bulk - Discontinued at Mosen Multi-Conductor 4 18 AWG 7/26 Copper, Bare Poly-Vinyl Chloride (PVC), Plenum 0.185 (4.70mm) Foil 100.0' (30.5m) Natural - Drain Wire 300 V 0°C ~ 75°C Alarm, Security, Sound
E2036S.30.10

E2036S.30.10

CABLE 6COND 18AWG GRY SHLD 50'

Prysmian Group

3636 0.00
- +

Ajouter au panier

Demander

E2036S.30.10

Datenblatt

Bulk - Discontinued at Mosen Multi-Conductor 6 18 AWG 7/26 Copper, Bare Poly-Vinyl Chloride (PVC) 0.221 (5.61mm) Foil 50.00' (15.24m) Gray - Drain Wire, Rip Cord 300 V -20°C ~ 75°C Alarm, Security, Sound
E2104S.30.86

E2104S.30.86

CABLE 4COND 22AWG NAT SHLD 50'

Prysmian Group

2550 0.00
- +

Ajouter au panier

Demander

E2104S.30.86

Datenblatt

Bulk - Discontinued at Mosen Multi-Conductor 4 22 AWG 7/30 Copper, Bare Poly-Vinyl Chloride (PVC), Plenum 0.147 (3.73mm) Foil 50.00' (15.24m) Natural - Drain Wire 300 V 0°C ~ 75°C Alarm, Security, Sound
E2106S.30.86

E2106S.30.86

CABLE 6COND 22AWG NAT SHLD 50'

Prysmian Group

3843 0.00
- +

Ajouter au panier

Demander

E2106S.30.86

Datenblatt

Bulk - Discontinued at Mosen Multi-Conductor 6 22 AWG 7/30 Copper, Bare Poly-Vinyl Chloride (PVC), Plenum 0.176 (4.47mm) Foil 50.00' (15.24m) Natural - Drain Wire 300 V 0°C ~ 75°C Alarm, Security, Sound
E2204S.30.86

E2204S.30.86

CABLE 4COND 18AWG NAT SHLD 50'

Prysmian Group

3566 0.00
- +

Ajouter au panier

Demander

E2204S.30.86

Datenblatt

Bulk - Discontinued at Mosen Multi-Conductor 4 18 AWG 7/26 Copper, Bare Poly-Vinyl Chloride (PVC), Plenum 0.185 (4.70mm) Foil 50.00' (15.24m) Natural - Drain Wire 300 V 0°C ~ 75°C Alarm, Security, Sound
C9009A.41.10

C9009A.41.10

CABLE 2COND 22AWG GRAY 500'

Prysmian Group

2299 0.00
- +

Ajouter au panier

Demander

C9009A.41.10

Datenblatt

Bulk Exzel™ Discontinued at Mosen Multi-Conductor 2 22 AWG 7/30 Copper, Tinned Poly-Vinyl Chloride (PVC) 0.167 (4.24mm) - 500.0' (152.4m) Gray - Rip Cord 300 V -30°C ~ 105°C -
C9009A.41.10

C9009A.41.10

CABLE 2COND 22AWG GRAY 100'

Prysmian Group

2795 0.00
- +

Ajouter au panier

Demander

C9009A.41.10

Datenblatt

Bulk Exzel™ Discontinued at Mosen Multi-Conductor 2 22 AWG 7/30 Copper, Tinned Poly-Vinyl Chloride (PVC) 0.167 (4.24mm) - 100.0' (30.5m) Gray - Rip Cord 300 V -30°C ~ 105°C -
C9034A.41.10

C9034A.41.10

CABLE 10COND 18AWG GRAY 500'

Prysmian Group

3082 0.00
- +

Ajouter au panier

Demander

C9034A.41.10

Datenblatt

Bulk Exzel™ Discontinued at Mosen Multi-Conductor 10 18 AWG 16/30 Copper, Tinned Poly-Vinyl Chloride (PVC) 0.381 (9.68mm) - 500.0' (152.4m) Gray - Rip Cord 300 V -30°C ~ 105°C -
C9034A.41.10

C9034A.41.10

CABLE 10COND 18AWG GRAY 100'

Prysmian Group

3022 0.00
- +

Ajouter au panier

Demander

C9034A.41.10

Datenblatt

Bulk Exzel™ Discontinued at Mosen Multi-Conductor 10 18 AWG 16/30 Copper, Tinned Poly-Vinyl Chloride (PVC) 0.381 (9.68mm) - 100.0' (30.5m) Gray - Rip Cord 300 V -30°C ~ 105°C -
C8122.41.86

C8122.41.86

CBL 2COND 18AWG PVC 50'

Prysmian Group

3867 0.00
- +

Ajouter au panier

Demander

C8122.41.86

Datenblatt

Spool - Discontinued at Mosen Multi-Conductor 2 (1 Pair) 18 AWG 19/30 Copper, Annealed Tinned Poly-Vinyl Chloride (PVC) 0.154 (3.91mm) - 50.00' (15.24m) Natural ASTM B-33 Flame Retardant 300 V -20°C ~ 75°C Communication, Control
C8122.41.86

C8122.41.86

CBL 2COND 18AWG PVC 100'

Prysmian Group

2266 0.00
- +

Ajouter au panier

Demander

C8122.41.86

Datenblatt

Spool - Discontinued at Mosen Multi-Conductor 2 (1 Pair) 18 AWG 19/30 Copper, Annealed Tinned Poly-Vinyl Chloride (PVC) 0.154 (3.91mm) - 100.0' (30.5m) Natural ASTM B-33 Flame Retardant 300 V -20°C ~ 75°C Communication, Control
C9131A.41.10

C9131A.41.10

CABLE 4COND 18AWG GRAY SHLD 500'

Prysmian Group

3732 0.00
- +

Ajouter au panier

Demander

C9131A.41.10

Datenblatt

Bulk Exzel™ Discontinued at Mosen Multi-Conductor 4 18 AWG 16/30 Copper, Tinned Poly-Vinyl Chloride (PVC) 0.260 (6.60mm) Foil 500.0' (152.4m) Gray - Drain Wire, Rip Cord 300 V -30°C ~ 105°C -
C9131A.41.10

C9131A.41.10

CABLE 4COND 18AWG GRAY SHLD 100'

Prysmian Group

3859 0.00
- +

Ajouter au panier

Demander

C9131A.41.10

Datenblatt

Bulk Exzel™ Discontinued at Mosen Multi-Conductor 4 18 AWG 16/30 Copper, Tinned Poly-Vinyl Chloride (PVC) 0.260 (6.60mm) Foil 100.0' (30.5m) Gray - Drain Wire, Rip Cord 300 V -30°C ~ 105°C -
E2102S.30.86

E2102S.30.86

CABLE 2COND 22AWG NAT SHLD 500'

Prysmian Group

2098 0.00
- +

Ajouter au panier

Demander

E2102S.30.86

Datenblatt

Bulk - Discontinued at Mosen Multi-Conductor 2 22 AWG 7/30 Copper, Bare Poly-Vinyl Chloride (PVC), Plenum 0.128 (3.25mm) Foil 500.0' (152.4m) Natural - Drain Wire 300 V 0°C ~ 75°C Alarm, Security, Sound
Total 42632 Records«Prev1... 15201521152215231524152515261527...2132Next»